HVAC replacement cost calculator

Enter the conditioned area, climate and system type with your quoted per-ton equipment price to get a rule-of-thumb size in tons and BTU/h and an itemised replacement cost with a range.

Your details

We have filled in typical numbers to get you started. Change any of them to match your situation; the estimate updates as you type.

Sizing (rule of thumb)

sq ft / m²

Heated and cooled living space only; exclude garage and unfinished basement.

Illustrative BTU/h per sq ft. A real system is sized with a Manual J load calculation that accounts for insulation, windows, orientation and air leakage.

More options (11)

Fine-tune the estimate. The starting values are typical, so you can skip this.

Equipment price per ton

CAD

Illustrative. Equipment only, per ton of nominal capacity. Replace with a dealer quote.

CAD

Illustrative. Equipment only, per ton of nominal capacity. Replace with a dealer quote.

CAD

Illustrative. Equipment only, per ton of nominal capacity. Replace with a dealer quote.

CAD

Illustrative. Equipment only, per ton of nominal capacity. Replace with a dealer quote.

Installation and other costs

CAD

Illustrative. Crew time, refrigerant, line set, electrical hook-up and commissioning.

CAD

Illustrative. Used when "Repair and seal" is selected.

CAD

Illustrative. Used when "Replace ductwork" is selected.

CAD

Illustrative. Mechanical permit; some areas also require an electrical permit.

CAD

Illustrative. Includes refrigerant recovery, which must be done by a certified technician.

How we got this number
StepFormulaWith your valuesResult
Cooling load (rule of thumb)Area (sq ft) × BTU/h per sq ft2000 × 2550,000 BTU/h
Tons (exact)BTU/h ÷ 12,00050000 ÷ 120004.17 tons
Nominal size (rounded up to half ton)ceil(tons ÷ 0.5) × 0.5ceil(4.17 ÷ 0.5) × 0.54.5 tons
Equipment (Heat pump (heating and cooling))Nominal tons × cost per ton4.5 × 2400.0010,800
TotalEquipment + labour + ductwork + permits + removal10800 + 3500 + 0 + 400 + 60015,300
RangeTotal × 0.85 to total × 1.1515300 × 0.85; 15300 × 1.1517,595
A newly laid brick wall

Estimates are for planning. They are not financial, tax, legal or engineering advice; check figures with a qualified professional before acting on them.

What this works out

The calculator multiplies floor area by a climate factor to get a load in BTU/h, converts to tons (12,000 BTU/h each) and rounds up to the next half ton, then prices equipment per ton and adds labour, ductwork, permits and removal. The sizing is a rule of thumb for budgeting only, not a Manual J load calculation; all prices are placeholders to replace with quotes.

The formula

Show the formula

Load (BTU/h) = area (sq ft) × BTU/h per sq ft. Tons = ceil(load ÷ 12,000 ÷ 0.5) × 0.5. Equipment = tons × cost per ton. Total = equipment + labour + ductwork + permits + removal. Range = total × 0.85 to total × 1.15.

An example

A 2,000 sq ft house in a moderate climate (25 BTU/h per sq ft): load 50,000 BTU/h = 4.17 tons, rounded up to 4.5 tons. Heat pump at an illustrative $2,000 per ton = $9,000; labour $3,000; no ductwork change; permits $300; removal $500. Total $12,800, range $10,880 to $14,720.

What the result means

Compare the nominal tons with what the installer proposes. If they quote a bigger unit without a load calculation, ask why: oversizing is the most common HVAC mistake and costs more to buy and to run. The per-ton equipment price is the number that separates a fair quote from an expensive one, so ask for equipment and labour as separate lines.

What is and is not included

The BTU/h-per-sq-ft factors are illustrative rules of thumb; real loads depend on insulation, windows, orientation, ceiling height, occupancy and air leakage, and only a Manual J (or equivalent) calculation gives a size you should buy. All prices are illustrative and vary by brand, efficiency rating (SEER2/HSPF2), region and season. Electrical panel upgrades, thermostat, zoning, line-set replacement and refrigerant type changes are not included unless added to labour.

Good to know where you are

United States: most jurisdictions require a mechanical permit; federal and utility incentives for heat pumps change by year and state and are not included. Canada: prices in CAD; cold-climate heat pumps are rated at low outdoor temperatures and may cost more per ton than the default; provincial rebate programmes are not included. In both countries, refrigerant recovery from the old unit must be done by a certified technician.

Common questions

Is this a Manual J calculation?

No. It is a square-footage rule of thumb for budgeting. A Manual J calculation uses the building envelope, windows, orientation and infiltration and is what an installer should run before you buy.

Why is the size rounded up to half a ton?

Residential split systems are sold in half-ton steps (1.5, 2, 2.5 tons and so on), so the next available size above the calculated load is what you would buy.

What is a ton of cooling?

12,000 BTU/h, about 3.5 kW. It comes from the heat needed to melt one ton of ice in 24 hours.

Does the heat pump option cover heating too?

Yes, a heat pump both heats and cools. In cold climates check the rated output at low outdoor temperatures; some installs keep a furnace as backup, which the Furnace + AC option approximates.

Should I replace the ductwork?

If ducts are leaky, undersized or in an unconditioned attic, repair or replacement can matter more to comfort than the equipment. Choose the ductwork option that matches the installer’s recommendation and enter their price.

Where the rules come from

    Last reviewed 2026-10-17 · Lumarc Studio editorial

    The numbers behind this calculator
    The numbers behind this calculator
    Ton of refrigeration1 ton = 12,000 BTU/h = 3.517 kWVerified · 2026-10-17
    BTU/h per sq ft by climate20 / 25 / 30 (illustrative rule of thumb, not Manual J)Illustrative
    Nominal size roundingRounded up to the next 0.5 ton (residential split systems are sold in half-ton steps)Illustrative
    Equipment price per tonIllustrative per system type; replace with quotesIllustrative
    Installation labourIllustrative flat figureIllustrative
    Ductwork repair / replacementIllustrative flat figuresIllustrative
    Permits, removalIllustrative flat figuresIllustrative
    Low/high range±15% of the total (illustrative)Illustrative
    Unit conversion1 m² = 10.7639 sq ft; 1 BTU/h = 0.29307 WVerified · 1959-07-01