Lumarc Calculators

Insulation cost and savings calculator

Enter the area, current and target R-value (or U-value), material and labour rates, heating degree days and your fuel price to get the install cost, annual saving, simple payback and net saving over 10 and 20 years.

Your details

We have filled in typical numbers to get you started. Change any of them to match your situation; the estimate updates as you type.

Area and insulation

Imperial: sq ft, R-values and °F degree-days. Metric: m², U-values (W/m²K) and °C degree-days.

sq ft / m²

Loft/attic floor, wall or floor area being upgraded.

R / U

Imperial: total R of the existing assembly in h·ft²·°F/BTU. Metric: existing U-value in W/m²K (higher U = more heat loss).

R / U

Imperial: R after the upgrade (must be higher than current). Metric: U after the upgrade (must be lower than current).

More options (14)

Fine-tune the estimate. The starting values are typical, so you can skip this.

Installation cost

CAD

Illustrative. Material only, per sq ft (imperial) or per m² (metric). Replace with a supplier price.

CAD

Illustrative. Material only, per sq ft (imperial) or per m² (metric). Replace with a supplier price.

CAD

Illustrative. Material only, per sq ft (imperial) or per m² (metric). Replace with a supplier price.

CAD

Illustrative. Material only, per sq ft (imperial) or per m² (metric). Replace with a supplier price.

CAD

Illustrative. Set to 0 for a DIY install.

Climate and heating

°F-days / °C-days

Illustrative national-average starting figure; replace with the value for your location (°F-days in imperial, °C-days in metric; base 65 °F / 15.5 °C).

CAD

Illustrative. From your bill, including delivery charges.

CAD

Illustrative. Used for electric resistance and heat pump heating.

CAD

Illustrative. US gallon.

%

Illustrative. AFUE or seasonal efficiency; 80–98% for modern appliances. Electric resistance is taken as 100%.

COP

Illustrative. Units of heat delivered per unit of electricity over the season (SCOP); used only for the heat pump option.

Horizon

years

Net saving is also shown for 10 and 20 years.

How we got this number
StepFormulaWith your valuesResult
Area in m²Area (sq ft) × 0.092903041000 × 0.0929030492.9 m²
U-value before1 ÷ (R × 0.17611)1 ÷ (11 × 0.17611)0.52 W/m²K
U-value after1 ÷ (R × 0.17611)1 ÷ (38 × 0.17611)0.15 W/m²K
Heating degree days (°C)°F-days ÷ 1.87000 ÷ 1.83,888.9 °C-days
Annual heat loss reductionArea × (U before − U after) × HDD × 24 ÷ 100092.903 × (0.5162 − 0.1494) × 3888.9 × 24 ÷ 10003,180.3 kWh/yr
Fuel energy savedHeat loss ÷ efficiency3180.3 ÷ 0.93,533.7 kWh/yr
Fuel quantity (therms)kWh ÷ kWh per therm3533.7 ÷ 29.3071120.57 therms
Annual fuel cost savingFuel quantity × price120.57 × 1.30156.75 /yr
Install cost (Fibreglass batt)Area × (material + labour per unit area)1000 sq ft × (1.20 + 1.00)2,200
Simple paybackInstall cost ÷ annual saving2200 ÷ 156.7514 years
Net saving over 20 yearsAnnual saving × 20 − install cost156.75 × 20 − 2200934.93
A bricklayer setting a brick in mortar

Estimates are for planning. They are not financial, tax, legal or engineering advice; check figures with a qualified professional before acting on them.

What this works out

The calculator converts R-values to U-values, works out the yearly heat loss through the element before and after the upgrade using heating degree days, divides by the appliance efficiency or heat pump COP to get fuel saved, and prices it at your tariff. It then compares the saving with the install cost. Cost and tariff defaults are placeholders; the physics is standard.

The formula

Show the formula

U = 1 ÷ (R × 0.17611) for imperial R-values. Heat loss reduction (kWh/yr) = area (m²) × (U before − U after) × HDD (°C-days) × 24 ÷ 1000. Fuel saved = heat loss ÷ efficiency (or ÷ COP). Annual saving = fuel saved × price. Payback = install cost ÷ annual saving. Net saving over N years = annual saving × N − install cost.

An example

A 1,000 sq ft attic floor (92.9 m²) upgraded from R-11 (U 0.516) to R-38 (U 0.149) in a 4,500 °F-day climate (2,500 °C-days): heat loss reduction 92.9 × 0.3668 × 2,500 × 24 ÷ 1000 = 2,044.5 kWh a year. A 90% gas furnace saves 2,271.7 kWh of gas = 77.51 therms, at an illustrative $1.50 a therm = $116.27 a year. Fibreglass batts at $1.00 plus $0.80 labour per sq ft cost $1,800, so simple payback is 15.5 years; net saving is −$637.32 after 10 years and $525.36 after 20.

What the result means

A payback under ten years is a good investment for most homes; over twenty means the existing insulation was already reasonable or fuel is cheap. The saving scales with the gap between current and target U-values, so topping up a nearly bare attic pays back far faster than adding to one that already has R-30. Fuel price and degree days are the two inputs most worth getting right for your own address.

What is and is not included

The model counts conduction through the insulated element only and assumes the whole heating season is driven by degree days with a 65 °F / 15.5 °C base; it ignores air leakage, thermal bridging, solar gain, internal gains, cooling-season savings and the thermostat behaviour of the occupants, so real savings are usually lower than the steady-state figure. Material, labour, degree-day and fuel-price defaults are illustrative and must be replaced with local figures. No price escalation or discount rate is applied.

Good to know where you are

United States: R-values and °F degree days are the convention; degree days for your city are published by NOAA, and attic targets by climate zone in the IECC. Canada: colder climates have far higher degree days than the default, so check your city; prices in CAD. United Kingdom: enter U-values in W/m²K and °C degree days; the Building Regulations set target U-values for upgraded elements and gas is billed per kWh, which the metric mode uses directly.

Common questions

What is the difference between R-value and U-value?

R is thermal resistance (higher is better); U is thermal transmittance, the reciprocal of R in SI units (lower is better). Imperial R-values are converted here with U = 1 ÷ (R × 0.17611).

Where do I find heating degree days?

Weather services publish them per station: NOAA in the US, Environment Canada, and the Met Office or degreedays.net in the UK. Use the annual total for the base temperature closest to 65 °F or 15.5 °C.

Why is the real saving usually lower?

Because the model assumes the house was fully heated to the base temperature before the upgrade and that all loss is conduction. Draughts, thermal bridging and people turning the heating down already reduce the loss the insulation can save.

Can I use it for walls or floors?

Yes; enter the wall or floor area and its R- or U-values. The degree-day model is the same, though floor losses to the ground are less sensitive to outdoor temperature than the model assumes.

Does the heat pump option need an efficiency?

It uses the seasonal COP field instead: a COP of 3 means one kWh of electricity delivers three kWh of heat, so the fuel saved is a third of the heat loss reduction.

Are grants or rebates included?

No. Subtract any grant from the install cost yourself; incentive schemes change often and vary by state, province and utility.

Where the rules come from

  • US Energy Information Administration, energy conversion calculators (heating oil 138,500 Btu per gallon; 1 therm = 100,000 Btu; 1 kWh = 3,412 Btu) · 2024-01-01

Last reviewed 2026-10-17 · Lumarc Studio editorial

The numbers behind this calculator
The numbers behind this calculator
Heat-loss modelQ = U × A × HDD × 24 (steady-state conduction through the insulated element only)Verified · 2021-01-01
R-value to U-valueU (W/m²K) = 1 ÷ (R × 0.17611); 1 h·ft²·°F/BTU = 0.17611 m²K/WVerified · 2008-01-01
Fuel energy content1 therm = 100,000 BTU = 29.307 kWh; heating oil 138,500 BTU/gal = 40.59 kWh/gal = 10.72 kWh/L; 1 kWh = 3,412 BTUSourced · 2024-01-01
Heating degree daysIllustrative national figures: US 4,500 °F-days, Canada 7,000 °F-days, UK 2,000 °C-days (editable)Illustrative
Current and target R/U valuesIllustrative: R-11 to R-38 (imperial), U 0.6 to 0.16 (metric)Illustrative
Material and labour cost per areaIllustrative per material and country; replace with quotesIllustrative
Fuel pricesIllustrative; take from your billIllustrative
Appliance efficiency90% for gas/oil, COP 3 for heat pump (illustrative); electric resistance 100%Illustrative
Price escalation and discountingNone: constant prices, simple paybackIllustrative