Heat pump running cost calculator
Enter your home’s heat demand, the heat pump’s SCOP, your boiler’s efficiency and the electricity and gas unit rates from your bill to see what each costs to run per year, the cost per kWh of heat, and the price ratio at which they break even.
Your details
We have filled in typical numbers to get you started. Change any of them to match your situation; the estimate updates as you type.
Heat demand
Sets a typical annual heat demand. Choose "Enter my own" and fill the next field if you know your figure (your gas bill in kWh × boiler efficiency is a good estimate).
Heat delivered to the home per year, space heating plus hot water. Used when home size is "Enter my own".
More options (9)
Fine-tune the estimate. The starting values are typical, so you can skip this.
Heat pump
Seasonal coefficient of performance for space heating: units of heat per unit of electricity. Use the figure in your MCS design or quote.
Efficiency when heating the cylinder to 50 °C or more. Only used if a hot water share is entered.
Pence per kWh from your bill. If you are on a standard variable tariff, Ofgem publishes the current price cap unit rate for your region. The default is a placeholder.
Gas boiler
Seasonal efficiency of the boiler you are comparing with. Modern condensing boilers achieve 85–92% in practice; older boilers less.
Pence per kWh from your bill, or the Ofgem price cap gas unit rate. The default is a placeholder.
Pence per day. Enter it if you would remove the gas supply after installing the heat pump, so the saving counts; 0 if you keep gas for cooking.
Installation
Total from your installer’s quote, before any grant.
Grant you expect to receive, if any. In England and Wales check the Boiler Upgrade Scheme (Ofgem); in Scotland check Home Energy Scotland. Leave 0 if unsure.
Years to run the cumulative comparison; 15 years is a common heat pump design life.
How we got this number
| Step | Formula | With your values | Result |
|---|---|---|---|
| Heat pump electricity | Space heat ÷ SCOP + hot water heat ÷ hot-water COP | 12000 ÷ 3 + 0 ÷ 2.5 | 4,000 kWh |
| Heat pump running cost | Electricity kWh × unit rate | 4000 × 25p | 1,000 GBP |
| Gas used by the boiler | Heat demand ÷ boiler efficiency | 12000 ÷ 85% | 14,118 kWh |
| Gas running cost | Gas kWh × unit rate + standing charge × 365 | 14118 × 6p + 0p × 365 | 847.06 GBP |
| Difference | Gas cost − heat pump cost | 847.06 − 1000 | -152.94 GBP |
| Break-even electricity-to-gas price ratio | Blended COP ÷ boiler efficiency | 3 ÷ 0.85 | 3.53 |
| Your electricity-to-gas price ratio | Electricity unit rate ÷ gas unit rate | 25 ÷ 6 | 4.17 |
Year by year
| Year | heatPump | gas | cumulative |
|---|---|---|---|
| Year 0 | 0 | 0 | -12,000 |
| Year 1 | 1,000 | 847.06 | -12,152.94 |
| Year 2 | 1,000 | 847.06 | -12,305.88 |
| Year 3 | 1,000 | 847.06 | -12,458.82 |
| Year 4 | 1,000 | 847.06 | -12,611.76 |
| Year 5 | 1,000 | 847.06 | -12,764.71 |
| Year 6 | 1,000 | 847.06 | -12,917.65 |
| Year 7 | 1,000 | 847.06 | -13,070.59 |
| Year 8 | 1,000 | 847.06 | -13,223.53 |
| Year 9 | 1,000 | 847.06 | -13,376.47 |
| Year 10 | 1,000 | 847.06 | -13,529.41 |
| Year 11 | 1,000 | 847.06 | -13,682.35 |
| Year 12 | 1,000 | 847.06 | -13,835.29 |
| Year 13 | 1,000 | 847.06 | -13,988.24 |
| Year 14 | 1,000 | 847.06 | -14,141.18 |
| Year 15 | 1,000 | 847.06 | -14,294.12 |

Estimates are for planning. They are not financial, tax, legal or engineering advice; check figures with a qualified professional before acting on them.
What this works out
The calculator converts annual heat demand into the electricity a heat pump would use (demand divided by SCOP) and the gas a boiler would burn (demand divided by efficiency), prices each at your unit rates, and reports the difference. It also shows the electricity-to-gas price ratio at which the two cost the same, so you can see how far your tariffs are from that line, and the payback on the installation if the heat pump is cheaper to run.
The formula
Show the formula
Heat pump electricity = space heat ÷ SCOP + hot water heat ÷ hot-water COP. Heat pump cost = electricity × electricity rate. Gas used = heat demand ÷ boiler efficiency. Gas cost = gas used × gas rate + standing charge × 365. Cost per kWh of heat: electricity rate ÷ COP, and gas rate ÷ efficiency. Break-even ratio = COP ÷ efficiency. Payback = (install cost − grant) ÷ (gas cost − heat pump cost), when positive.
An example
A semi-detached house needing 12,000 kWh of heat a year. A heat pump with a SCOP of 3.0 uses 4,000 kWh of electricity; at 25p per kWh that is £1,000.00 a year. An 85% efficient gas boiler burns 14,118 kWh of gas; at 6p per kWh that is £847.06 a year with no standing charge counted. The heat pump costs £152.94 a year more to run. Per kWh of heat, the heat pump costs 8.33p and gas 7.06p. The break-even electricity-to-gas price ratio is 3.0 ÷ 0.85 = 3.53; at 25p and 6p the actual ratio is 4.17, so on these rates there is no running-cost payback on a £12,000 installation.
What the result means
If the saving per year is positive, the heat pump is cheaper to run and the payback figure shows how many years of that saving repay the net installation cost. If it is negative, the heat pump costs more to run at your tariffs; the break-even ratio tells you how much cheaper electricity would need to be relative to gas, or how high a SCOP you would need, for the two to match. A heat-pump-specific electricity tariff, a higher SCOP from a well-designed low-temperature system, or removing the gas standing charge can each move the answer.
What is and is not included
The heat demand presets are rough figures for typical UK homes; your actual demand depends on insulation, size and how warm you keep the house, so use your gas bill (annual gas kWh × boiler efficiency) if you have one. Unit rates and the install cost are placeholders to replace with your bill, the current Ofgem price cap and your quote. The SCOP must come from your installer’s design: it depends on flow temperature, emitter sizing and your climate. Electricity standing charges are left out because you pay them with or without a heat pump. Prices are held flat, no maintenance, servicing or boiler replacement cost is included, and no discounting is applied.
Good to know where you are
England and Wales: the Boiler Upgrade Scheme, administered by Ofgem, offers a grant towards an MCS-certified heat pump installation; check the current amount and eligibility before entering it. Scotland: Home Energy Scotland offers grants and loans. Northern Ireland has separate schemes. The Ofgem price cap applies to standard variable tariffs in Great Britain; fixed tariffs and heat-pump-specific tariffs can differ substantially, and the cap does not apply in Northern Ireland.
Common questions
Where do I find my unit rates?
On your energy bill or your supplier’s online account, shown in pence per kWh for electricity and gas. If you are on a standard variable tariff, Ofgem publishes the price cap unit rates for each region and quarter.
What SCOP should I use?
The seasonal coefficient of performance in your MCS design or quote. Well-designed systems running at low flow temperatures commonly achieve 3.0–4.0; a system running radiators at high temperatures may be below 3.0.
Why does hot water have a separate COP?
Heating a cylinder to 50 °C or more needs a higher flow temperature than space heating, which lowers the heat pump’s efficiency. Enter a hot water share if you want that reflected; otherwise the SCOP is applied to everything.
How do I estimate my heat demand from my gas bill?
Multiply the annual gas use in kWh by your boiler’s efficiency (about 0.85 for a typical condensing boiler). Subtract any gas used for cooking if it is significant.
Is the Boiler Upgrade Scheme grant included?
Only if you enter it. Grant amounts and eligibility change, so confirm the current figure with Ofgem or your MCS installer, who applies on your behalf.
Why is a heat pump sometimes dearer to run than gas?
Because UK electricity has cost roughly three to four times as much per kWh as gas. A heat pump with a SCOP of 3.0 against an 85% boiler only breaks even when the price ratio is below about 3.5; a higher SCOP or a cheaper electricity tariff shifts that.
Where the rules come from
- Ofgem, energy price cap · 2026-10-17
Source for current standard variable tariff unit rates and standing charges; no rate is assumed here.
- Ofgem, Boiler Upgrade Scheme · 2026-10-17
Check current grant level and eligibility; no amount is assumed here.
- MCS (Microgeneration Certification Scheme) · 2026-10-17
Heat pump design, SCOP estimates and installer certification.
Last reviewed 2026-10-17 · Lumarc Studio editorial
Related calculators
The numbers behind this calculator
| Heat demand by home size | Flat 6,000; terraced 9,000; semi-detached 12,000; detached 18,000 kWh a year | Illustrative |
| Heat pump SCOP | 3.0 for space heating; 2.5 for hot water if a share is entered | Illustrative |
| Boiler efficiency | 85% seasonal | Illustrative |
| Electricity and gas unit rates | Placeholder pence-per-kWh rates; replace with your bill or the current Ofgem price cap rates | Illustrative |
| Installed cost | Placeholder; replace with your quote | Illustrative |
| Grant | 0 unless you enter an amount; no scheme value is assumed | Your entry |
| Energy units | Gas and heat are both measured in kWh, as on UK bills (1 kWh = 3,412 BTU) | Verified · 2026-10-17 |
| Price movement | Rates held flat over the comparison period; no discounting | Illustrative |