Lumarc Calculators

Heat pump running cost calculator

Enter your home’s heat demand, the heat pump’s SCOP, your boiler’s efficiency and the electricity and gas unit rates from your bill to see what each costs to run per year, the cost per kWh of heat, and the price ratio at which they break even.

Your details

We have filled in typical numbers to get you started. Change any of them to match your situation; the estimate updates as you type.

Heat demand

Sets a typical annual heat demand. Choose "Enter my own" and fill the next field if you know your figure (your gas bill in kWh × boiler efficiency is a good estimate).

kWh

Heat delivered to the home per year, space heating plus hot water. Used when home size is "Enter my own".

%

Share of the heat demand that is hot water, which a heat pump makes at a lower efficiency. 0 treats everything at the SCOP; 15–25% is typical.

More options (9)

Fine-tune the estimate. The starting values are typical, so you can skip this.

Heat pump

Seasonal coefficient of performance for space heating: units of heat per unit of electricity. Use the figure in your MCS design or quote.

Efficiency when heating the cylinder to 50 °C or more. Only used if a hot water share is entered.

p/kWh

Pence per kWh from your bill. If you are on a standard variable tariff, Ofgem publishes the current price cap unit rate for your region. The default is a placeholder.

Gas boiler

%

Seasonal efficiency of the boiler you are comparing with. Modern condensing boilers achieve 85–92% in practice; older boilers less.

p/kWh

Pence per kWh from your bill, or the Ofgem price cap gas unit rate. The default is a placeholder.

p/day

Pence per day. Enter it if you would remove the gas supply after installing the heat pump, so the saving counts; 0 if you keep gas for cooking.

Installation

GBP

Total from your installer’s quote, before any grant.

GBP

Grant you expect to receive, if any. In England and Wales check the Boiler Upgrade Scheme (Ofgem); in Scotland check Home Energy Scotland. Leave 0 if unsure.

years

Years to run the cumulative comparison; 15 years is a common heat pump design life.

How we got this number
StepFormulaWith your valuesResult
Heat pump electricitySpace heat ÷ SCOP + hot water heat ÷ hot-water COP12000 ÷ 3 + 0 ÷ 2.54,000 kWh
Heat pump running costElectricity kWh × unit rate4000 × 25p1,000 GBP
Gas used by the boilerHeat demand ÷ boiler efficiency12000 ÷ 85%14,118 kWh
Gas running costGas kWh × unit rate + standing charge × 36514118 × 6p + 0p × 365847.06 GBP
DifferenceGas cost − heat pump cost847.06 − 1000-152.94 GBP
Break-even electricity-to-gas price ratioBlended COP ÷ boiler efficiency3 ÷ 0.853.53
Your electricity-to-gas price ratioElectricity unit rate ÷ gas unit rate25 ÷ 64.17

Year by year

YearheatPumpgascumulative
Year 000-12,000
Year 11,000847.06-12,152.94
Year 21,000847.06-12,305.88
Year 31,000847.06-12,458.82
Year 41,000847.06-12,611.76
Year 51,000847.06-12,764.71
Year 61,000847.06-12,917.65
Year 71,000847.06-13,070.59
Year 81,000847.06-13,223.53
Year 91,000847.06-13,376.47
Year 101,000847.06-13,529.41
Year 111,000847.06-13,682.35
Year 121,000847.06-13,835.29
Year 131,000847.06-13,988.24
Year 141,000847.06-14,141.18
Year 151,000847.06-14,294.12
A paint roller leaning against a freshly painted wall

Estimates are for planning. They are not financial, tax, legal or engineering advice; check figures with a qualified professional before acting on them.

What this works out

The calculator converts annual heat demand into the electricity a heat pump would use (demand divided by SCOP) and the gas a boiler would burn (demand divided by efficiency), prices each at your unit rates, and reports the difference. It also shows the electricity-to-gas price ratio at which the two cost the same, so you can see how far your tariffs are from that line, and the payback on the installation if the heat pump is cheaper to run.

The formula

Show the formula

Heat pump electricity = space heat ÷ SCOP + hot water heat ÷ hot-water COP. Heat pump cost = electricity × electricity rate. Gas used = heat demand ÷ boiler efficiency. Gas cost = gas used × gas rate + standing charge × 365. Cost per kWh of heat: electricity rate ÷ COP, and gas rate ÷ efficiency. Break-even ratio = COP ÷ efficiency. Payback = (install cost − grant) ÷ (gas cost − heat pump cost), when positive.

An example

A semi-detached house needing 12,000 kWh of heat a year. A heat pump with a SCOP of 3.0 uses 4,000 kWh of electricity; at 25p per kWh that is £1,000.00 a year. An 85% efficient gas boiler burns 14,118 kWh of gas; at 6p per kWh that is £847.06 a year with no standing charge counted. The heat pump costs £152.94 a year more to run. Per kWh of heat, the heat pump costs 8.33p and gas 7.06p. The break-even electricity-to-gas price ratio is 3.0 ÷ 0.85 = 3.53; at 25p and 6p the actual ratio is 4.17, so on these rates there is no running-cost payback on a £12,000 installation.

What the result means

If the saving per year is positive, the heat pump is cheaper to run and the payback figure shows how many years of that saving repay the net installation cost. If it is negative, the heat pump costs more to run at your tariffs; the break-even ratio tells you how much cheaper electricity would need to be relative to gas, or how high a SCOP you would need, for the two to match. A heat-pump-specific electricity tariff, a higher SCOP from a well-designed low-temperature system, or removing the gas standing charge can each move the answer.

What is and is not included

The heat demand presets are rough figures for typical UK homes; your actual demand depends on insulation, size and how warm you keep the house, so use your gas bill (annual gas kWh × boiler efficiency) if you have one. Unit rates and the install cost are placeholders to replace with your bill, the current Ofgem price cap and your quote. The SCOP must come from your installer’s design: it depends on flow temperature, emitter sizing and your climate. Electricity standing charges are left out because you pay them with or without a heat pump. Prices are held flat, no maintenance, servicing or boiler replacement cost is included, and no discounting is applied.

Good to know where you are

England and Wales: the Boiler Upgrade Scheme, administered by Ofgem, offers a grant towards an MCS-certified heat pump installation; check the current amount and eligibility before entering it. Scotland: Home Energy Scotland offers grants and loans. Northern Ireland has separate schemes. The Ofgem price cap applies to standard variable tariffs in Great Britain; fixed tariffs and heat-pump-specific tariffs can differ substantially, and the cap does not apply in Northern Ireland.

Common questions

Where do I find my unit rates?

On your energy bill or your supplier’s online account, shown in pence per kWh for electricity and gas. If you are on a standard variable tariff, Ofgem publishes the price cap unit rates for each region and quarter.

What SCOP should I use?

The seasonal coefficient of performance in your MCS design or quote. Well-designed systems running at low flow temperatures commonly achieve 3.0–4.0; a system running radiators at high temperatures may be below 3.0.

Why does hot water have a separate COP?

Heating a cylinder to 50 °C or more needs a higher flow temperature than space heating, which lowers the heat pump’s efficiency. Enter a hot water share if you want that reflected; otherwise the SCOP is applied to everything.

How do I estimate my heat demand from my gas bill?

Multiply the annual gas use in kWh by your boiler’s efficiency (about 0.85 for a typical condensing boiler). Subtract any gas used for cooking if it is significant.

Is the Boiler Upgrade Scheme grant included?

Only if you enter it. Grant amounts and eligibility change, so confirm the current figure with Ofgem or your MCS installer, who applies on your behalf.

Why is a heat pump sometimes dearer to run than gas?

Because UK electricity has cost roughly three to four times as much per kWh as gas. A heat pump with a SCOP of 3.0 against an 85% boiler only breaks even when the price ratio is below about 3.5; a higher SCOP or a cheaper electricity tariff shifts that.

Where the rules come from

  • Ofgem, energy price cap · 2026-10-17

    Source for current standard variable tariff unit rates and standing charges; no rate is assumed here.

  • Ofgem, Boiler Upgrade Scheme · 2026-10-17

    Check current grant level and eligibility; no amount is assumed here.

  • MCS (Microgeneration Certification Scheme) · 2026-10-17

    Heat pump design, SCOP estimates and installer certification.

Last reviewed 2026-10-17 · Lumarc Studio editorial

The numbers behind this calculator
The numbers behind this calculator
Heat demand by home sizeFlat 6,000; terraced 9,000; semi-detached 12,000; detached 18,000 kWh a yearIllustrative
Heat pump SCOP3.0 for space heating; 2.5 for hot water if a share is enteredIllustrative
Boiler efficiency85% seasonalIllustrative
Electricity and gas unit ratesPlaceholder pence-per-kWh rates; replace with your bill or the current Ofgem price cap ratesIllustrative
Installed costPlaceholder; replace with your quoteIllustrative
Grant0 unless you enter an amount; no scheme value is assumedYour entry
Energy unitsGas and heat are both measured in kWh, as on UK bills (1 kWh = 3,412 BTU)Verified · 2026-10-17
Price movementRates held flat over the comparison period; no discountingIllustrative