Lumarc Calculators

Solar panel savings calculator

Enter your system size, expected yield, the tariffs on your bill and the installer’s quote to see the year-1 saving, payback period, net benefit over the system’s life and the cost per kWh it generates.

Your details

We have filled in typical numbers to get you started. Change any of them to match your situation; the estimate updates as you type.

System

kW

Peak DC capacity of the panels, from the quote (kWp).

kWh/kW/yr

kWh generated per kW of panels per year. Take it from your installer’s quote or a solar resource tool (PVWatts for the US, the PVGIS tool for the UK, the Clean Energy Council guide for Australia). It depends on location, roof direction, tilt and shading.

%

Share of generation used in the house rather than exported. Typical homes without a battery use 25–50%.

More options (8)

Fine-tune the estimate. The starting values are typical, so you can skip this.

Tariffs

GBP

Enter the unit rate from your own electricity bill. The default is a round placeholder, not a published rate.

GBP

What your retailer pays for exported energy: a net-metering credit or export rate in the US, the feed-in tariff in Australia, your Smart Export Guarantee rate in the UK. Enter the figure from your retailer.

%

Assumed yearly rise in both the import and export tariffs. 0 keeps prices flat.

Cost

GBP

Total price from the installer’s quote, before any incentive.

GBP

Amount you expect to receive, if any. Check the current rules: the US residential clean energy credit (IRS), Australian small-scale technology certificates (Clean Energy Regulator), and any UK scheme in force. Leave 0 if unsure.

GBP

Cleaning, monitoring or an inverter replacement fund, per year. 0 if none.

Lifetime

%

Yearly fall in output. Manufacturer warranties commonly state 0.4–0.7% per year.

years
How we got this number
StepFormulaWith your valuesResult
Year-1 generationSystem size × specific yield4 kW × 900 kWh/kW3,600 kWh
Self-consumed energyGeneration × self-consumption share3600 × 40%1,440 kWh
Exported energyGeneration − self-consumed3600 − 14402,160 kWh
Year-1 bill savingSelf-consumed × import tariff + exported × export tariff1440 × 0.25 + 2160 × 0.15684
Net installed costInstalled cost − incentive7000 − 07,000
Savings over 25 yearsΣ year-1 saving × (1 − degradation)^(year − 1) × (1 + escalation)^(year − 1)684 across 25 years at 0.5% degradation and 2% escalation20,537.25
Net benefitTotal savings − total maintenance − net installed cost20537.25 − 0 − 700013,537.25
Lifetime cost per kWh(Net installed cost + total maintenance) ÷ total generation(7000 + 0) ÷ 848010.08 per kWh
Simple paybackNet installed cost ÷ year-1 saving7000 ÷ 68410.23 years

Year by year

Yeargenerationsavingcumulative
Year 000-7,000
Year 13,600684-6,316
Year 23,582694.19-5,621.81
Year 33,564704.54-4,917.27
Year 43,546715.03-4,202.24
Year 53,529725.69-3,476.55
Year 63,511736.5-2,740.05
Year 73,493747.47-1,992.58
Year 83,476758.61-1,233.97
Year 93,458769.91-464.06
Year 103,441781.39317.33
Year 113,424793.031,110.36
Year 123,407804.841,915.2
Year 133,390816.842,732.04
Year 143,373829.013,561.04
Year 153,356841.364,402.4
Year 163,339853.95,256.3
Year 173,323866.626,122.92
Year 183,306879.537,002.45
Year 193,289892.647,895.09
Year 203,273905.948,801.02
Year 213,257919.449,720.46
Year 223,240933.1310,653.59
Year 233,224947.0411,600.63
Year 243,208961.1512,561.78
Year 253,192975.4713,537.25
A brick wall in raking sunlight

Estimates are for planning. They are not financial, tax, legal or engineering advice; check figures with a qualified professional before acting on them.

What this works out

The calculator multiplies system size by a specific yield to get year-1 generation, splits it into the share you use at home (valued at your import tariff) and the share you export (valued at your export or feed-in tariff), then rolls that saving forward year by year with panel degradation and tariff escalation. The cumulative cash flow against the net installed cost gives the payback year and the net benefit.

The formula

Show the formula

Generation = kW × yield. Saving (year 1) = generation × self-consumption × import tariff + generation × (1 − self-consumption) × export tariff. Saving (year n) = saving (year 1) × (1 − degradation)^(n − 1) × (1 + escalation)^(n − 1). Net benefit = Σ savings − maintenance × years − (installed cost − incentive). Simple payback = net cost ÷ year-1 saving. Lifetime cost per kWh = (net cost + maintenance) ÷ Σ generation.

An example

A 6 kW system with a specific yield of 1,200 kWh/kW generates 7,200 kWh in year 1. With 40% self-consumption, 2,880 kWh offsets imports at 0.25 per kWh (720.00) and 4,320 kWh is exported at 0.05 per kWh (216.00), a year-1 saving of 936.00. On a net installed cost of 9,000 with no maintenance, the simple payback is 9.6 years. With 0.5% yearly degradation and 2% tariff escalation over 25 years, total savings are 28,103.61, the net benefit is 19,103.61, the cumulative cash flow turns positive during year 10 (9.1 years), and the lifetime cost per kWh generated is 0.053.

What the result means

The year-1 saving is the figure to compare with your current annual bill. The payback period tells you how long the system must keep working before it has repaid its cost; anything under the panel warranty period (usually 25 years) means the system is expected to leave you ahead. The lifetime cost per kWh is what you effectively pay for each unit the panels produce; compare it with your import tariff. A higher self-consumption share improves every result because imports avoided are worth more than exports sold.

What is and is not included

Every default tariff, feed-in rate, system price and yield is a round illustrative number: change each one to the figures on your bill, your retailer’s export rate and your quote. The specific yield depends on your location, roof direction, tilt and shading; take it from an installer’s estimate or a solar resource tool rather than the default. No incentive is assumed unless you enter one, and no loan interest, inflation discounting, insurance or inverter replacement is included unless you add a maintenance figure. Self-consumption is held constant across years. Tariffs are escalated at one rate; real tariffs move unevenly.

Good to know where you are

United States: check the residential clean energy credit with the IRS and your state and utility programmes; whether export is credited at the retail rate (net metering) or a lower export rate depends on your utility and state. Australia: small-scale technology certificates (STCs) are usually applied as a point-of-sale discount by the installer; check the Clean Energy Regulator for the current scheme, and ask your retailer for the feed-in tariff. United Kingdom: export is paid under the Smart Export Guarantee at a rate set by each licensed supplier (Ofgem oversees the scheme); check which supplier offers the best rate and whether any installation incentive is currently in force.

Common questions

Where do I find my specific yield?

Your installer’s quote normally states the expected annual generation; divide it by the system size in kW. Free tools such as PVWatts (US) or PVGIS (Europe) estimate it from your postcode, roof direction and tilt.

What self-consumption share should I use?

Homes where someone is in during the day, or that run appliances on timers, typically use 30–50% of generation. If you are out all day it may be 20–30%. A battery raises it; the solar battery payback calculator models that.

Why is the export tariff so much lower than the import tariff?

Retailers pay a wholesale-based rate for exported energy but charge a retail rate (including network, metering and retail costs) for imports. This is why using your own generation is worth more than exporting it.

Does the calculator include the US tax credit or Australian STCs?

Only if you enter the amount in the incentive field. Schemes change; check the current rules with the IRS or the Clean Energy Regulator and your installer before relying on a figure.

What does the degradation rate do?

It reduces generation each year. At 0.5% per year the panels produce about 88.6% of their year-1 output in year 25, which is roughly what manufacturer performance warranties guarantee.

Does the result account for a loan or inflation?

No. The cash flows are undiscounted and assume you pay the installed cost up front. If you finance the system, add the interest to the installed cost or to the maintenance figure for a rough allowance.

Where the rules come from

  • Internal Revenue Service (IRS), residential clean energy credit guidance · 2026-10-17

    Check the current credit percentage, eligibility and expiry; no amount is assumed here.

  • Clean Energy Regulator (Australia), Small-scale Renewable Energy Scheme · 2026-10-17

    STC values vary with location, system size and the certificate market.

  • Ofgem, Smart Export Guarantee · 2026-10-17

    Export rates are set by each supplier, not by the regulator.

  • NREL PVWatts calculator · 2026-10-17

    Source for a location-specific yield estimate (US and worldwide).

Last reviewed 2026-10-17 · Lumarc Studio editorial

The numbers behind this calculator
The numbers behind this calculator
Specific yield defaultsUS 1,400, Australia 1,450, UK 900 kWh per kW per yearIllustrative
Self-consumption share40% of generation used in the homeIllustrative
Import and export tariffsRound placeholder rates; replace with the unit rates on your billIllustrative
Installed costRound placeholder; replace with your installer’s quoteIllustrative
Panel degradation0.5% of output per year, compoundingIllustrative
Tariff escalation2% per year applied to both tariffsIllustrative
Incentives0 unless you enter an amount; no scheme value is assumedYour entry
Time value of moneyCash flows are summed without discounting; no finance cost is includedIllustrative