Enter your system size, expected yield, the tariffs on your bill and the installer’s quote to see the year-1 saving, payback period, net benefit over the system’s life and the cost per kWh it generates.
Your details
We have filled in typical numbers to get you started. Change any of them to match your situation; the estimate updates as you type.
System
Peak DC capacity of the panels, from the quote (kWp).
kWh generated per kW of panels per year. Take it from your installer’s quote or a solar resource tool (PVWatts for the US, the PVGIS tool for the UK, the Clean Energy Council guide for Australia). It depends on location, roof direction, tilt and shading.
Share of generation used in the house rather than exported. Typical homes without a battery use 25–50%.
More options (8)
Fine-tune the estimate. The starting values are typical, so you can skip this.
Tariffs
Enter the unit rate from your own electricity bill. The default is a round placeholder, not a published rate.
What your retailer pays for exported energy: a net-metering credit or export rate in the US, the feed-in tariff in Australia, your Smart Export Guarantee rate in the UK. Enter the figure from your retailer.
Assumed yearly rise in both the import and export tariffs. 0 keeps prices flat.
Cost
Total price from the installer’s quote, before any incentive.
Amount you expect to receive, if any. Check the current rules: the US residential clean energy credit (IRS), Australian small-scale technology certificates (Clean Energy Regulator), and any UK scheme in force. Leave 0 if unsure.
Cleaning, monitoring or an inverter replacement fund, per year. 0 if none.
Lifetime
Yearly fall in output. Manufacturer warranties commonly state 0.4–0.7% per year.
How we got this number
| Step | Formula | With your values | Result |
|---|---|---|---|
| Year-1 generation | System size × specific yield | 6 kW × 1400 kWh/kW | 8,400 kWh |
| Self-consumed energy | Generation × self-consumption share | 8400 × 40% | 3,360 kWh |
| Exported energy | Generation − self-consumed | 8400 − 3360 | 5,040 kWh |
| Year-1 bill saving | Self-consumed × import tariff + exported × export tariff | 3360 × 0.17 + 5040 × 0.05 | 823.2 |
| Net installed cost | Installed cost − incentive | 18000 − 0 | 18,000 |
| Savings over 25 years | Σ year-1 saving × (1 − degradation)^(year − 1) × (1 + escalation)^(year − 1) | 823.2 across 25 years at 0.5% degradation and 2% escalation | 24,716.76 |
| Net benefit | Total savings − total maintenance − net installed cost | 24716.76 − 0 − 18000 | 6,716.76 |
| Lifetime cost per kWh | (Net installed cost + total maintenance) ÷ total generation | (18000 + 0) ÷ 197870 | 0.09 per kWh |
| Simple payback | Net installed cost ÷ year-1 saving | 18000 ÷ 823.2 | 21.87 years |
Year by year
| Year | generation | saving | cumulative |
|---|---|---|---|
| Year 0 | 0 | 0 | -18,000 |
| Year 1 | 8,400 | 823.2 | -17,176.8 |
| Year 2 | 8,358 | 835.47 | -16,341.33 |
| Year 3 | 8,316 | 847.91 | -15,493.42 |
| Year 4 | 8,275 | 860.55 | -14,632.87 |
| Year 5 | 8,233 | 873.37 | -13,759.5 |
| Year 6 | 8,192 | 886.38 | -12,873.12 |
| Year 7 | 8,151 | 899.59 | -11,973.53 |
| Year 8 | 8,110 | 912.99 | -11,060.53 |
| Year 9 | 8,070 | 926.6 | -10,133.94 |
| Year 10 | 8,029 | 940.4 | -9,193.53 |
| Year 11 | 7,989 | 954.42 | -8,239.11 |
| Year 12 | 7,949 | 968.64 | -7,270.48 |
| Year 13 | 7,910 | 983.07 | -6,287.41 |
| Year 14 | 7,870 | 997.72 | -5,289.69 |
| Year 15 | 7,831 | 1,012.58 | -4,277.11 |
| Year 16 | 7,792 | 1,027.67 | -3,249.44 |
| Year 17 | 7,753 | 1,042.98 | -2,206.45 |
| Year 18 | 7,714 | 1,058.52 | -1,147.93 |
| Year 19 | 7,675 | 1,074.3 | -73.63 |
| Year 20 | 7,637 | 1,090.3 | 1,016.67 |
| Year 21 | 7,599 | 1,106.55 | 2,123.22 |
| Year 22 | 7,561 | 1,123.04 | 3,246.26 |
| Year 23 | 7,523 | 1,139.77 | 4,386.02 |
| Year 24 | 7,485 | 1,156.75 | 5,542.78 |
| Year 25 | 7,448 | 1,173.99 | 6,716.76 |

Estimates are for planning. They are not financial, tax, legal or engineering advice; check figures with a qualified professional before acting on them.
What this works out
The calculator multiplies system size by a specific yield to get year-1 generation, splits it into the share you use at home (valued at your import tariff) and the share you export (valued at your export or feed-in tariff), then rolls that saving forward year by year with panel degradation and tariff escalation. The cumulative cash flow against the net installed cost gives the payback year and the net benefit.
The formula
Show the formula
Generation = kW × yield. Saving (year 1) = generation × self-consumption × import tariff + generation × (1 − self-consumption) × export tariff. Saving (year n) = saving (year 1) × (1 − degradation)^(n − 1) × (1 + escalation)^(n − 1). Net benefit = Σ savings − maintenance × years − (installed cost − incentive). Simple payback = net cost ÷ year-1 saving. Lifetime cost per kWh = (net cost + maintenance) ÷ Σ generation.
An example
A 6 kW system with a specific yield of 1,200 kWh/kW generates 7,200 kWh in year 1. With 40% self-consumption, 2,880 kWh offsets imports at 0.25 per kWh (720.00) and 4,320 kWh is exported at 0.05 per kWh (216.00), a year-1 saving of 936.00. On a net installed cost of 9,000 with no maintenance, the simple payback is 9.6 years. With 0.5% yearly degradation and 2% tariff escalation over 25 years, total savings are 28,103.61, the net benefit is 19,103.61, the cumulative cash flow turns positive during year 10 (9.1 years), and the lifetime cost per kWh generated is 0.053.
What the result means
The year-1 saving is the figure to compare with your current annual bill. The payback period tells you how long the system must keep working before it has repaid its cost; anything under the panel warranty period (usually 25 years) means the system is expected to leave you ahead. The lifetime cost per kWh is what you effectively pay for each unit the panels produce; compare it with your import tariff. A higher self-consumption share improves every result because imports avoided are worth more than exports sold.
What is and is not included
Every default tariff, feed-in rate, system price and yield is a round illustrative number: change each one to the figures on your bill, your retailer’s export rate and your quote. The specific yield depends on your location, roof direction, tilt and shading; take it from an installer’s estimate or a solar resource tool rather than the default. No incentive is assumed unless you enter one, and no loan interest, inflation discounting, insurance or inverter replacement is included unless you add a maintenance figure. Self-consumption is held constant across years. Tariffs are escalated at one rate; real tariffs move unevenly.
Good to know where you are
United States: check the residential clean energy credit with the IRS and your state and utility programmes; whether export is credited at the retail rate (net metering) or a lower export rate depends on your utility and state. Australia: small-scale technology certificates (STCs) are usually applied as a point-of-sale discount by the installer; check the Clean Energy Regulator for the current scheme, and ask your retailer for the feed-in tariff. United Kingdom: export is paid under the Smart Export Guarantee at a rate set by each licensed supplier (Ofgem oversees the scheme); check which supplier offers the best rate and whether any installation incentive is currently in force.
Common questions
Where do I find my specific yield?
Your installer’s quote normally states the expected annual generation; divide it by the system size in kW. Free tools such as PVWatts (US) or PVGIS (Europe) estimate it from your postcode, roof direction and tilt.
What self-consumption share should I use?
Homes where someone is in during the day, or that run appliances on timers, typically use 30–50% of generation. If you are out all day it may be 20–30%. A battery raises it; the solar battery payback calculator models that.
Why is the export tariff so much lower than the import tariff?
Retailers pay a wholesale-based rate for exported energy but charge a retail rate (including network, metering and retail costs) for imports. This is why using your own generation is worth more than exporting it.
Does the calculator include the US tax credit or Australian STCs?
Only if you enter the amount in the incentive field. Schemes change; check the current rules with the IRS or the Clean Energy Regulator and your installer before relying on a figure.
What does the degradation rate do?
It reduces generation each year. At 0.5% per year the panels produce about 88.6% of their year-1 output in year 25, which is roughly what manufacturer performance warranties guarantee.
Does the result account for a loan or inflation?
No. The cash flows are undiscounted and assume you pay the installed cost up front. If you finance the system, add the interest to the installed cost or to the maintenance figure for a rough allowance.
Where the rules come from
- Internal Revenue Service (IRS), residential clean energy credit guidance · 2026-10-17
Check the current credit percentage, eligibility and expiry; no amount is assumed here.
- Clean Energy Regulator (Australia), Small-scale Renewable Energy Scheme · 2026-10-17
STC values vary with location, system size and the certificate market.
- Ofgem, Smart Export Guarantee · 2026-10-17
Export rates are set by each supplier, not by the regulator.
- NREL PVWatts calculator · 2026-10-17
Source for a location-specific yield estimate (US and worldwide).
Last reviewed 2026-10-17 · Lumarc Studio editorial
Related calculators
The numbers behind this calculator
| Specific yield defaults | US 1,400, Australia 1,450, UK 900 kWh per kW per year | Illustrative |
| Self-consumption share | 40% of generation used in the home | Illustrative |
| Import and export tariffs | Round placeholder rates; replace with the unit rates on your bill | Illustrative |
| Installed cost | Round placeholder; replace with your installer’s quote | Illustrative |
| Panel degradation | 0.5% of output per year, compounding | Illustrative |
| Tariff escalation | 2% per year applied to both tariffs | Illustrative |
| Incentives | 0 unless you enter an amount; no scheme value is assumed | Your entry |
| Time value of money | Cash flows are summed without discounting; no finance cost is included | Illustrative |